- HackRF PortaPack H4M with current Mayhem firmware
 
  - MicroSD card (FAT32) with free space for IQ recordings
 
  - An antenna matched to the target band
 
  - Local, lawful test signals (e.g., simple OOK/ASK remotes, sensors, or a test RF source)
 
  - Capture: Records an IQ file (.wav or .bin) at a chosen sample rate and frequency.
 
  - Replay: Transmits the saved IQ file back at the original center frequency, matched sample rate, and controlled TX gain.
 
  - Keep recordings short and centered on the signal to improve replay fidelity.
 
  - From the main menu, navigate to Capture.
 
  - This is where you can configure your recording settings.
 
  - Center Frequency: Set exactly to the target carrier frequency (e.g., 433.92 MHz for many ISM remotes).
 
  - Sample Rate: Choose the smallest rate that fully contains the signal’s bandwidth. Start with 2 Msps for narrowband bursts; increase only if needed.
 
  - Gain: Adjust LNA/VGA gain until the signal clearly stands above the noise without clipping.
 
  - File Name/Location: Use a unique, short filename (avoid spaces) and ensure there is enough free space on the SD card.
 
  - Press the Rec button to begin recording.
 
  - Trigger the source signal (e.g., press the remote button) while the recorder is active.
 
  - Stop recording immediately after the burst to keep the file tight and easier to replay.
 
  - Re-open the Capture app and quickly re-tune around the capture frequency to confirm the original signal characteristics.
 
  - Optionally, some builds allow quick playback monitoring (RX-side) to confirm non-empty content.
 
  - Go to the Replay app.
 
  - Select the recorded file from the SD card list; confirm filename and size look correct.
 
  - Ensure the device is set to the same frequency as the capture center frequency.
 
  - Sample Rate: Match the original capture sample rate exactly to preserve timing.
 
  - TX Gain: Start low (e.g., 0–8 dB) and increase gradually while observing the target’s response.
 
  - Loop: Keep off for initial tests; enable only if the target needs repeated frames.
 
  - DC Offset / IQ Balance (if available): Leave default unless you have evidence of mirror/offset issues.
 
  - Ensure legal compliance and that the frequency is allowed for your test scenario.
 
  - Press Play/Transmit to send the IQ recording.
 
  - Evaluate the target’s reaction. If no effect, adjust TX gain slightly or re-check frequency alignment.
 
  - Wrong Center Frequency: Re-check the exact carrier; even small offsets can break narrowband devices.
 
  - Clipped Capture: If the original was clipped, try capturing at lower RX gain.
 
  - Undersampled: Use a higher capture sample rate if the signal bandwidth was larger than expected.
 
  - Rolling Codes: Many modern remotes use rolling codes; a single capture may not work again. Start with simpler targets.
 
  - Keep captures short and start just before the expected burst; end right after to minimize noise.
 
  - Log the frequency, sample rate, gains, environment, and timing for each capture.
 
  - For very weak signals, add a band-pass filter and moderate LNA to increase SNR without saturating.
 
  - Use antennas tuned for the band; wideband antennas are convenient but not always optimal.
 
  - Only replay signals in controlled, lawful environments and on permitted frequencies.
 
  - Prefer shielded or low-power setups for bench validation.
 